kind added
title The engine can set how many jobs one of your computers runs at once, where it can follow
pr 0
surface
engine
invalidates
The app wire could read a factory's computers (`factory.runners`) but not change their capacity. `factory.runner_slots {factory, runner, slots}` now does, for the OWNER of that computer, one computer at a time. It cannot pause, remove or add a computer, change its checkouts or write to GitHub.
`GET /v1/runners` carried no statement of what a runner's `slots` may be, so a client had to copy the number 8. It now carries `slots_policy {min, max, requires_live}` from the server's own constant, and ONLY a factory that enforces the guard below sends it. A directory without it is an older factory, for which the engine refuses the change before any request.
`PUT /v1/runners/{runner}` wrote capacity for a worker that could not follow it (an older binary stays at its fixed 2 however often it restarts). It accepts `require_live_capacity: true`, judged under the same lock as the write against the NEWEST attach of that machine; a worker that restarted onto an older binary since the caller read the directory is refused with 409 and nothing changes. A client without the field keeps the earlier behaviour exactly.
`PUT /v1/runners/{runner}` answered every refusal with no statement of whether anything had been saved. It now carries `X-Codeaf-Phase: pre-mutation` on a refusal made before the first change and clears it just before the change, so a failure of the save or of the event after it reads as uncertain.
The roster's `live_capacity` for a machine came from whichever of its credential rows was seen last, which presence pings reorder. It now comes from the newest ATTACH (a new `Attached` time on the row, never moved by presence); attaches that cannot be ordered must all attest, so an ambiguity can only withhold a write.

A distinct optional feature, factory.runner_manage, adds one method, factory.runner_slots {factory, runner, slots}, answered with the same three fields once the factory said 200 or 204. FactoryCapabilities.runner_manage says the engine serves it. Whether THIS factory and THIS computer can take it is read from the directory (slots_policy, live_capacity), never assumed from the feature.

Params are exactly those three: runner is the computer's id as listed (bounded, opaque, one path segment), slots is an integer from 1 to api.MaxRunnerSlots with no default, and a route, verb, body, token or checkout list is bad_params. Each call asks GET /v1/me and GET /v1/runners with the credential held now; the computer's owner must be the handle GET /v1/me names. Being the operator gives no power over another person's computer. A computer that is not live, or a factory whose policy is absent or is not the expected one, is conflict before any write leaves.

The engine sends one PUT and never retries. Only a 4xx or 501 carrying the phase marker is a definite refusal, in fixed words. A dropped connection, a timeout, a redirect, a 5xx, an unmarked refusal (the factory saves the number and then records the event) or an unexpected success such as 202 is uncertain. If the sign-in changes during any wait, nothing about the computer is revealed; after the write the answer is a neutral uncertain. The receipt repeats what was asked; read factory.runners for what is granted.