Repository navigation
Spectrum: fan speed, enclosure and drying for 72 filaments (new #767 fields) - #816
Conversation
…ilamentCollective#767 fields) Values from the manufacturers' product pages / technical data sheets, mapped as described in the PR. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01B8a6Te45fbpikDxHXroeG8
Automated reviewCovers Changed values: 0 of 196 proven
ChecksNo issues found by the automated checks. AI reviewAdds the #767 print-parameter fields (fan speed, enclosure, drying) to 72 Spectrum filaments, all as the body describes. I read the PA6 CF15 and PA12 CF15 datasheets: their fan, enclosure and drying values match the diff, but I could not check the other lines. One inconsistency between the body and the diff needs fixing before merge. Inline on the diff: 2 findings. claude-haiku-5-5 · $0.03 · reviewed d7d727f Auto-mergeThe Checks ran on d7d727f · workflow run Maintainers: ✅ LGTM & merge |
coffandro
left a comment
There was a problem hiding this comment.
LGTM! Thanks for the contribution, it'll be up on SP and the dataset at about 00:00 Danish time.
Also sorry for the "radio chatter", we're working out the kinks on a new system :D
Summary
Follow-up to #735 / #767: fills the new print-parameter fields for 72 Spectrum filaments:
min_fan_speed42,max_fan_speed70,enclosure58,dry_temperature13,dry_time13. Sources: the product pages of shop.spectrumfilaments.com ("Cooling fan", "Closed chamber") and Spectrum's technical data sheets (drying). Where a line has many colour pages, all of them were read; the number after the link says how many more.Left out: enclosure for 14 technical materials (ABS GP450, PA6 variants, PC 275, PP …) — the shop says "recommended", the data sheet says a closed chamber is needed; fan speed for Thermatech PA and GreenyHT, where shop and data sheet give different values.
spectrum/ABS/abs_fr_v0spectrum/ABS/abs_gp450spectrum/ABS/abs_kevlarspectrum/ABS/abs_medicalspectrum/ABS/smart_absspectrum/ASA/asaspectrum/ASA/asa_275spectrum/ASA/asa_kevlarspectrum/ASA/asa_x_cf10spectrum/ASA/asa_x_gf10spectrum/ASA/cf_asaspectrum/HIPS/hipsspectrum/HIPS/hips_xspectrum/PA12/pa12_cf15spectrum/PA6/pa6_cf15spectrum/PA6/pa6_cs20_fr_v0spectrum/PA6/pa6_gk10spectrum/PA6/pa6_low_warpspectrum/PA6/pa6_low_warp_cf15sspectrum/PA6/pa6_low_warp_gf30spectrum/PA6/pa6_neat_bkspectrum/PA6/pa6_neat_ntspectrum/PA6/thermatech_paspectrum/PC/pc_275spectrum/PCTG/pctg_cf10spectrum/PCTG/pctg_gf10spectrum/PCTG/pctg_premiumspectrum/PET/pet_cf15spectrum/PETG/petg_carbonspectrum/PETG/petg_fr_v0spectrum/PETG/petg_fx120spectrum/PETG/petg_glitterspectrum/PETG/petg_glow_in_the_darkspectrum/PETG/petg_ht100spectrum/PETG/petg_mattspectrum/PETG/petg_premiumspectrum/PETG/petg_premium_high_speedspectrum/PETG/ptfespectrum/PETG/r_petgspectrum/PLA/aquaprintspectrum/PLA/flameguard_plaspectrum/PLA/greenyhtspectrum/PLA/greenyprospectrum/PLA/high_speed_plaspectrum/PLA/huracan_plaspectrum/PLA/lw_pla_ultrafoamspectrum/PLA/pastello_plaspectrum/PLA/pla_carbonspectrum/PLA/pla_crystalspectrum/PLA/pla_electrically_conductivespectrum/PLA/pla_glitterspectrum/PLA/pla_glow_in_the_darkspectrum/PLA/pla_magic_silkspectrum/PLA/pla_mattspectrum/PLA/pla_metalspectrum/PLA/pla_naturespectrum/PLA/pla_premiumspectrum/PLA/pla_premium_highspeedspectrum/PLA/pla_silkspectrum/PLA/pla_silk_rainbowspectrum/PLA/pla_thermoactivespectrum/PLA/pla_toughspectrum/PLA/r_plaspectrum/PLA/safeguard_plaspectrum/PLA/stone_age_plaspectrum/PLA/woodspectrum/PP/ppspectrum/PPS/pps_am230spectrum/TPU/s_flex_85aspectrum/TPU/s_flex_90aspectrum/TPU/s_flex_98aspectrum/TPU/s_flex_carbonHow source values were mapped (same rules for every brand in this series):
dry_temperature= the lower temperature,max_dry_temperature=the upper one (only where the field was empty),
dry_time= the upper number of hours.max_fan_speed100 only;"ON" and similar left out.
not_needed, "recommended…" →recommended, "yes / needed / heated chamber" →required.dry_temperatureabove an existingmax_dry_temperatureis left out.python -m ofd validate: all validations passed (no new warnings). Indentation of each file kept as it was.🤖 Generated with Claude Code
https://claude.ai/code/session_01B8a6Te45fbpikDxHXroeG8