A Cisco IOS-like CLI for Horaco / ZX-SWTG124AS web-managed switches — the cheap AliExpress 2.5G/10G switches (Realtek-based, firmware ~V1.9) that expose only an HTTP UI on port 80 (no SSH, telnet, or SNMP) and whose VLAN page is a clumsy per-VLAN port-membership matrix plus a separate per-port PVID form.
horaco.py wraps that web UI so you can manage VLANs and trunk/access ports with
familiar commands — abbreviation, ? help, and Tab completion included — instead of
clicking radio buttons.
switch# show interfaces
Interface Cap Link Speed Admin PVID Mode Description VLANs (u=untag,t=tag)
Tw1 2.5G Link Up 2500M Enable 10 ex-trunk AP uplink 11t,42t,43t
Tw2 2.5G Link Up 1000M Enable 42 access - 42u
Te1 10G Link Up 10G Enable 1 trunk - 10t,11t,12t
Only dependency: requests (plus PyYAML). Python 3.8+.
The inventory is a plaintext switches.yml when one exists — see switches.example.yml — looked for, in order, at $HORACO_SWITCHES, the current directory, then this script's directory and its parents (handy when the tool is a git submodule and the inventory lives in the parent repo). Without one, it is read from OpenBao at secret/switches, with the irix-infrastructure repo's scripts/bao-token.sh (found by walking up from this script).
switches:
myswitch:
host: 192.168.1.10
user: admin
password: changeme
ports: 6pip install requests pyyaml
python horaco.py --list # list configured switches
python horaco.py myswitch # interactive IOS-style shell
python horaco.py myswitch -c "show vlan"
python horaco.py myswitch -n -c "..." # --dry-run: print the HTTP POSTs, change nothingEvery keyword can be abbreviated to any unambiguous prefix, exactly like IOS —
sh vl, conf t, sw tr allow vlan add 44. Ambiguous prefixes are rejected with the
candidates (sh v → "Ambiguous: show vlan, show version").
?instantly (no Enter) lists what's valid at the cursor, each with a description —?,show ?,interface ?,switchport trunk ?. Works mid-word (sh?); your line is preserved underneath.<Tab>completes the current word (unique → fills in + space; ambiguous → common prefix + lists candidates).- Arrow keys, Home/End, Backspace/Delete, Ctrl-A/E/U and command history all work.
The interactive shell uses a small built-in raw-mode line editor — no extra
dependencies. When stdin isn't a TTY it falls back to plain line input, and ?/Tab
still work via typing show ? + Enter.
Interfaces use Cisco media-type names: TwoGigabitEthernet1-4 (the 2.5G ports,
abbrev tw1) and TenGigabitEthernet1-2 (the 10G ports, abbrev te1). Ranges
work: interface range tw1-4, interface te1,te2.
show vlan # VLAN table: name, untagged/tagged ports
show interfaces [status] # link, negotiated speed, admin, PVID, mode, membership
show running-config # reconstructed IOS-style config
show version # model / firmware / MAC / IP
configure terminal
vlan 50 # create / enter a VLAN
name Guest
no vlan 50 # delete a VLAN
interface TwoGigabitEthernet2 # abbrev "tw2"; 10G ports are TenGigabitEthernet1-2 ("te1")
description Server rack # local-only label (see below); 'no description' clears
switchport access vlan 42 # untagged member + PVID 42, accept untagged
switchport mode access # strip tags -> untagged in the access/PVID VLAN
switchport mode trunk # allow ALL VLANs, accept all frames (keeps native/PVID)
switchport mode exclusive-trunk # allow ALL VLANs, accept TAGGED ONLY (native retained but ignored)
switchport trunk native vlan 5 # native = untagged member + PVID (default is 1)
no switchport trunk native vlan # reset native back to VLAN 1
switchport trunk allowed vlan 10,12,777 # narrow the trunk to this tagged set
switchport trunk allowed vlan add 44 # add to tagged set (leaves native/PVID alone)
switchport trunk allowed vlan remove 44
shutdown / no shutdown
end
write memory # persist to flash (the web UI's "Save")
Every page in the switch's web UI is mapped to an IOS-flavoured command. Read-only
show commands are safe to run live; write commands honour -n/--dry-run, and the
truly disruptive ones prompt [y/N] before acting.
Show / monitoring (read-only):
show ip # mgmt IP / netmask / gateway / DHCP state
show mac address-table # learned (dynamic) MAC table
show mac address-table static # static MAC entries
show spanning-tree # loop protocol + STP global + STP per-port
show qos # port-to-queue + queue scheduler
show storm-control # per-port storm filters
show ip igmp snooping # IGMP snooping state + entries
show etherchannel summary # port-channel (link-aggregation) groups
show monitor # port mirroring session
show isolation # port isolation matrix
show jumbo-frame # configured jumbo MTU
show eee # Energy Efficient Ethernet state
show rate-limit # per-port bandwidth limits
show port-security # per-port MAC-count limits
Global config (configure terminal):
jumbo-frame {1522|1536|1552|9216|16383} # max frame size
ip igmp snooping / no ip igmp snooping # IGMP snooping
energy-efficient-ethernet / no ... # 802.3az EEE
# The switch has ONE global loop mechanism. Pick a non-STP mode here, or pick STP
# below — they are mutually exclusive (the same hardware "Loop function" selector).
loop-protection {off|loop-detection|loop-prevention} # global loop mechanism
no loop-protection # mechanism off
spanning-tree mode {stp|rstp} # set loop mechanism = Spanning Tree, + version
no spanning-tree # loop mechanism off
spanning-tree priority <0-61440 step 4096> # bridge priority
spanning-tree max-age <sec> / hello-time <sec> / forward-time <sec>
qos scheduler strict <queue> # queue 1-8 -> strict priority
qos scheduler wrr <queue> <weight> # queue 1-8, weight 1-15 (WRR)
port-channel <1-2> mode {on|active|passive} interface <iface-range> # create/modify LAG
no port-channel <1-2> # delete the group
monitor session source <iface> {rx|tx|both} destination <iface> # port mirror
no monitor session # delete mirror
mac address-table static <MAC> vlan <vid> interface <iface> # static MAC
no mac address-table static <index> # delete static MAC by row index
clear mac address-table dynamic # flush learned MACs (exec/config)
System (DANGEROUS — gated, dry-run encouraged):
ip address <A.B.C.D> <mask> <gw> # set management IP (confirm)
ip address dhcp # management IP via DHCP (confirm)
username <name> password <pass> # change admin account (confirm)
Interface config (interface ... then):
speed {auto|10|100|1000|2500|10g} # 10G ports reject 10/100M
duplex {auto|half|full} # half only valid for 10/100M
flowcontrol {on|off} # 802.3x flow control
qos priority <1-8> # port default priority queue
rate-limit {ingress|egress} <kbps> / no rate-limit {ingress|egress}
storm-control {broadcast|multicast|unknown-unicast|unknown-multicast} level <kbps>
no storm-control {broadcast|multicast|unknown-unicast|unknown-multicast}
isolation <iface-range> / no isolation # block forwarding to listed ports
channel-group <1-2> mode {on|active|passive} # add this port to a port-channel
loop-protection / no loop-protection # apply/exempt the global loop mechanism here
port-security maximum <n> / no port-security # per-port learned-MAC limit
spanning-tree cost <0-200000000> # 0 = auto
spanning-tree port-priority <0-240 step 16>
spanning-tree link-type {point-to-point|shared|auto}
spanning-tree portfast / no spanning-tree portfast # edge port
Tools (exec; DANGEROUS ones gated):
copy running-config backup <path> # download config blob (safe GET)
copy backup running-config <path> # restore config blob (confirm)
boot system # enter firmware-upgrade mode (confirm)
reload # reboot the switch (confirm)
erase startup-config / factory-reset # restore factory defaults (confirm)
- The switch stores VLAN membership per VLAN (each VLAN lists which ports are
untagged / tagged / not-member). horaco.py reads the whole table, flips the ports you
named, and re-POSTs only the VLANs that changed — so
switchport access vlan Non one port doesn't disturb the others. - PVID (port default VLAN) is a separate form; access/native commands set it,
allowed vlan add/removedeliberately does not — preserving a common PVID→empty-VLAN "drop untagged" trunk trick. - The three accepted-frame-types map to modes:
access= Untag-only,trunk= All,exclusive-trunk= Tag-only. - Auth: the login form sets cookie
admin=md5(user+password). The switch keeps a single server-side admin session, so horaco.py POSTs the login form once on connect before reading (the cookie alone returns blank data on a cold session).
The ZX-SWTG124AS firmware has no port-name/description field on the device, so
description ... is stored locally in a descriptions.yml sidecar (next to your
inventory), keyed by switch name → port. It shows in show interfaces /
show running-config but is never written to the switch. Port capability (2.5G vs 10G)
is fixed by hardware and shown in the Cap column.
- Only one admin session at a time — close the web UI before using the CLI, or reads may come back empty / contended.
- One-shot (
-c) runs auto-save to flash when anything changed; the interactive shell prompts before saving on exit. Use-n/--dry-runto preview POSTs. - These are dumb L2 switches: no LACP, no L3. Trunk = tagged member of the allowed VLANs; access = untagged member + matching PVID.
Developed against ZX-SWTG124AS (6-port, firmware V1.9, Jan 2024). Other Horaco /
rebadged Realtek models that share the same vlan.cgi / port.cgi web UI are likely
to work; set ports: to your port count. PRs welcome.