Predbat-led EV charger control: shared mixin, and on automatically for GE, Ohme and Zappi (folds #5284 + #5311) - #5448
Open
chalfontchubby wants to merge 31 commits into
Open
chalfontchubby wants to merge 31 commits into
chalfontchubby wants to merge 31 commits into
Conversation
Ohme, myenergi and GivEnergy EVC each carry their own copy of the same control loop. CarChargerControl owns it once: read the per-car plan, charge inside a window and stop outside one, re-apply on drift, and release on read only or when the control switch is turned off, with the switch persisted across restarts. Components supply only the charger-specific send, release, connected and drift checks. Nothing uses it yet; the components move onto it in following commits. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
GivEnergy EVC control moves onto CarChargerControl. The component keeps what is GivEnergy's own: which chargers exist and in what order, whether a car is connected, and the start-charge / stop-charge commands. Behaviour is unchanged: the switch keeps its storage key, chargers without a car are still left alone, and release still only restarts a charger Predbat had stopped. The EVC read only check now falls back to the set_read_only arg, like the other chargers, rather than the switch entity; the fallback only applies before Predbat sets the attribute at startup. The test double's get_arg answers set_read_only from the same flag as its switch, as Predbat does. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Zappi control moves onto CarChargerControl. The component keeps what is myenergi's own: Fast inside a window and Stopped outside one, drift detected from the polled mode, and release back to the saved mode or Eco+. One deliberate change: a Zappi with no car to follow (more Zappis than num_cars, briefly true while auto-config's num_cars reaches the base) is now left alone rather than Stopped, matching what GivEnergy EVC control already did. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Ohme control moves onto CarChargerControl. The component keeps what is Ohme's own: max charge inside a window and pause outside one, drift detected from the session mode, and release back to Ohme's smart schedule with the user's target percent restored. Ohme has no control switch, so read only stays the only release. Its inline plan parser goes too, in favour of the shared one. That fixes a New Year case the copy missed: read just after midnight on 1 January, a window that started on 31 December parsed as the following December, so a charge running across midnight was paused. A release Ohme refuses is now retried on the next control cycle rather than attempted once, so a paused car is not stranded by one failed call. The control tick is wrapped the way myenergi's already is: a refused command logs a warning instead of failing the whole run, which would otherwise repeat every minute while read only stays on. The mixin now checks for a switch before touching storage, so a component with no switch never needs a storage attribute. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… retry refused GE commands - A charger Predbat holds that falls beyond the cars it follows (num_cars dropped) was never commanded again, left charging or stopped with nobody in control. apply() now releases it. - GivEnergy's async_send_evc_command() reports a refusal by returning None, so a refused release was taken as done and a stopped charger stranded - the failure the Ohme and myenergi retries already close. GE charger control now raises EVCCommandFailed on a refusal, so the command is not recorded and is tried again next cycle; GE's run loop catches it as a warning, as Ohme's and myenergi's already do. A refused start or stop is retried the same way rather than recorded as sent. - Docstring for a nested test helper. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…eased Zappi forgets its mode Found by a later review, in code from this PR: - Releasing, releasing a charger whose car has gone, and driving from the plan ran as one loop, so the first charger to refuse a command stopped every charger after it - and each cycle retried in the same order, so they stayed blocked. With two Zappis held Stopped and read only on, a refusing Zappi 1 left Zappi 2 Stopped for good. Each charger is now handled on its own; the first failure is still raised after the rest have had their turn, for the run loop to log and retry. A charger is forgotten as soon as its own release goes through, so a retry re-sends only to the one that refused. - A Zappi released on its own (its car gone when num_cars dropped) kept its saved mode, so taking it back later saved nothing new and the next release restored the stale mode. The saved mode is now dropped once that Zappi's release goes through. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…arger Charger control now decides per car whether Octopus Intelligent is in charge of the charger. Where Octopus delivers its dispatches by driving the charger itself, Predbat leaves it alone - releasing it if it was holding it - so the two never fight. Where Octopus drives the car, or there is no Intelligent car, Predbat drives the charger from the car slot sensor, which then carries the Octopus dispatches, so the car cannot charge outside them on its own timers. Octopus car N is the Nth wired Intelligent device, and the Octopus component already records whether each is a charge point. When that cannot be told - slots from outside the Octopus component, or before it has discovered its devices - the charger is left alone, unless the component's control setting is explicitly true. Nothing turns control on by default yet; that follows. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
ge_cloud_evc_control no longer defaults to false. Left unset, control follows ge_cloud_automatic_evc: setting that is the user asking Predbat to plan for the car, and it is what maps each charger to its car. An explicit false keeps control off, and only an explicit true warns when a prerequisite is missing. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
ohme_control no longer defaults to false. Left unset, control follows ohme_automatic, which registers the car. Where the Intelligent slots come from the Ohme, Octopus drives the charger and Predbat still leaves it alone - logged as Info for an unset control, and as a warning only when ohme_control was explicitly set true. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…tomatic myenergi_zappi_control no longer defaults to false. Left unset, control turns on only when the user wrote myenergi_automatic or myenergi_automatic_zappi into apps.yaml themselves. Both default on, so following their values alone - the rule GE and Ohme use - would switch every Zappi user to Predbat control on upgrade, and a Zappi held off between windows can no longer divert solar in Eco/Eco+. The options considered are recorded in enable_control()'s docstring for review. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… Intelligent A new "Predbat starting and stopping your charger" section in car-charging.md sets out when each charger's control turns on while its setting is unset, the upgrade change for existing automatic users, and what happens on Octopus Intelligent depending on whether Octopus drives the charger or the car. The per-setting entries in apps-yaml.md and components.md now describe the unset default instead of false. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…er start a charge handing over Found by review before opening the stage 2 PR: - Read is_charger from the car's own wired octopus_intelligent_slot sensor instead of pairing car N with the Nth sorted Octopus device. Both the Octopus and Kraken components publish it there, so E.ON/EDF SmartFlex users are covered and a slot list in a different order can no longer pair a car with another car's device. - Only wait for Octopus discovery when the Octopus component runs its automatic setup. With octopus_automatic off it never wires the slots, so control never turned on. "Cannot tell yet" also gets its own log line rather than claiming the car is on IOG. - Handing a charger to Octopus no longer starts it. A normal release undoes a stop so a car is never stranded, but here Octopus decides when to charge: a GE charger Predbat stopped is left for Octopus, an Ohme has max charge turned off before it is resumed into its smart schedule, and a Zappi returns to its own mode, Eco+ in place of Fast. - The control settings have no default, which also skipped get_arg()'s boolean conversion, so a quoted "false" or a 0 read as set. parse_control_setting() normalises them to None, True or False in each component. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…imit are set Predbat drives an Ohme with max charge, which overrides the target set in the Ohme app, so car_charging_battery_size and car_charging_limit are all that stop a charge. Left at their defaults (100 kWh, 100%) the car would be charged to full. Unset ohme_control now waits for both to be in apps.yaml and logs why; an explicit ohme_control: true is still the user's call. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…opus Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…pus drives follows its dispatch sensor - switch.predbat_octopus_intelligent_charging only changes Predbat's own planning: Octopus goes on switching a charger that is its Intelligent device whatever the switch says. The device is now judged first, so turning the switch off no longer has Predbat fight Octopus for that charger. For a car Octopus drives, the switch still decides whether the charger follows the dispatches or Predbat's own plan. - Where Octopus drives the car, the charger also runs while the car's dispatch sensor is on. The plan carries the dispatches but is only republished every 5 minutes and leaves out a dispatch Octopus has not given any energy yet, so the charger held the car off for the first minutes of a new dispatch. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While Predbat drives a charger it holds it off outside the planned windows, so a visitor's car could not charge - and stage 2 turns control on by default. Each component (GE, myenergi, Ohme) now publishes switch.predbat_<component>_guest_charging beside its control. On, Predbat releases the charger as it does for read only mode, so it runs on its own settings; how the guest charges is chosen on the charger itself. It turns itself off when a connected car is unplugged, on chargers that can tell (GE), and otherwise after GUEST_CHARGING_MAX_HOURS (12). It is deliberately not persisted, so a restart puts Predbat back in charge. The guest's charging is still counted as the car's. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…or Ohme Both report whether a car is plugged in - the Zappi's plug status, the Ohme's UNPLUGGED status - so guest charging now ends on unplug for every charger, not just GE. A new charger_control_car_plugged() hook carries it, separate from charger_control_connected(), so how Predbat drives an empty Zappi or Ohme is unchanged. An unknown plug state reads as plugged in, leaving the 12 hour limit. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ends are judged by the clock Found by review before opening the stage 2 PR: - Guest charging ended on any unplug, including the owner's car being unplugged to make way for the guest. Only a car plugged in after the switch went on now ends it (empty, plugged in, empty again); a guest who plugged in first is left to the 12 hour limit or a manual off. - A GE status blip (offline, unavailable, unknown) read as an unplug and ended guest charging. Only "available" and "idle" count as empty now, as the Zappi and Ohme already treat unknown states as plugged in. - The charger followed the dispatch sensor's on/off state, which only refreshes every couple of minutes and so ran the charger past the end of a dispatch. The dispatch times on the sensor are now judged against the clock, in both the Octopus and the Kraken formats, falling back to the state for a sensor with no times. - A toggle on the guest switch now flips it rather than turning it off. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…rger A dispatch sensor that does not say which device Octopus drives (the Octopus Energy integration, for one) leaves the charger uncontrolled for good, and was only an Info line. It is now a warning naming the component's own setting to set true. Waiting for the Octopus component to discover its devices, which normally clears within a cycle or two, stays Info. Each reason is logged once, and again only when it changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…g a charger (#5311 review) Only the Octopus component was waited for. After a restart a Kraken (E.ON/EDF SmartFlex) user's charger could be driven before Kraken had wired octopus_intelligent_slot - stopping a GE charger mid-dispatch, which the hand-over on the next cycle then left stopped. Kraken wires its devices in its first successful run, from cache or fresh discovery, so until it has started the charger is left alone. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…it, and stop waiting on discovery after 15 minutes (#5311 review) - Cannot tell whether Octopus drives a charger: a charger Predbat had stopped was let go without being started, as if Octopus were taking it over. With nobody known to take it over, a GE charger was left stopped indefinitely. It is now released as usual; the non-starting hand-over is kept for a charger Octopus is known to drive. - Waiting for Octopus or Kraken discovery is bounded at 15 minutes. A Kraken component whose first run never succeeds (a failed login) otherwise left every unwired car's charger uncontrolled for good. The log line now names both components. - The apps.yaml default's literal "re:" string, before its regex matches, is no longer read as a dispatch sensor - which on every restart warned users with no Intelligent sensor to set a control override they do not need. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…at a discovery that never finishes as cannot tell (#5311 review) Releasing during discovery started a charge Predbat had stopped whenever the Octopus or Kraken component restarted, and driving the charger once the wait ran out could fight Kraken if it was the one driving it. While discovery is under way the charger is now left as it is and still held, so it is settled either way once discovery finishes. After 15 minutes Predbat still cannot tell, so it warns once and hands back a charger it holds, as for a dispatch sensor that does not say. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…r is known (#5311 review) The wait's start was only cleared when discovery was asked about with nothing discovering, which stops happening once every car's driver is known. A later component restart could then find the old start and count the wait as already over. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…its own schedule stays the car plan otherwise Main's #5401 now takes the car plan from Ohme's own schedule when Predbat is not controlling the charger, so a default user already gets a plan that matches what the charger will do. Turning control on by default would override that schedule - one the user may have set up deliberately - with max charge, which also overrides the Ohme app's target. ohme_control goes back to a false default; GE and Zappi keep their automatic defaults. The size and limit guard for an unset ohme_control goes, as there is no unset default any more. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…alone when Octopus drives the car, unless asked to follow it When the car itself is the Octopus Intelligent device, the car starts and stops its own charge. Predbat now leaves the charger alone by default, handing over a charger it held without starting a charge, as it does when Octopus drives the charger. The new expert-mode switch, default off, has Predbat drive the charger to the car's dispatches instead, so the car cannot also charge on its own timers. The Ohme follows the same switch: with it on, ohme_control can run while Octopus drives the car, where #5405 otherwise stands it down. A change of the switch is picked up on the next Ohme poll. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…llowing Predbat's own plan with Intelligent charging off, and log only real Ohme changes (#5311 review) - Octopus driving the car means nobody drives the charger, so a charger Predbat had stopped is released as usual (GE started, Zappi back to its own mode including Fast) rather than handed over without starting, which left it stopped through every dispatch. - With switch.predbat_octopus_intelligent_charging off Predbat plans the car itself, so it still drives the charger to that plan whatever the new switch says. - An Ohme poll that sees only the new switch change logs that change, and only re-decides control while Octopus drives another device - not the Octopus tariff change it used to report. - The log points at expert mode for the switch, and the class docstring says the charger is left alone by default. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ging off while Octopus drives the car (#5311 review) The shared charger rule drives a charger for a car Octopus drives when switch.predbat_octopus_intelligent_charging is off, as Predbat then plans the car itself; the Ohme stood control down there regardless. It now follows the same rule, and re-decides when either switch changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…harger value as cannot tell (local review) Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Contributor
There was a problem hiding this comment.
🟡 Changes recommended
Ohme’s live Intelligent handoff uses the unsafe release order, and persistence failures can be silently ignored.
2 open findings
What changed in this PR
Introduces shared Predbat-led EV charger control for GivEnergy, Ohme, and myenergi, including automatic activation, Intelligent dispatch handling, and guest charging.
Changes:
- Adds the shared
CarChargerControlmixin. - Migrates three charger integrations and adds extensive tests.
- Updates configuration and user documentation.
| File | Description |
|---|---|
apps/predbat/car_charger_control.py |
Adds shared charger-control logic. |
apps/predbat/gecloud.py |
Migrates GivEnergy charger control. |
apps/predbat/myenergi.py |
Migrates Zappi charger control. |
apps/predbat/ohme.py |
Migrates Ohme control and Intelligent handling. |
apps/predbat/components.py |
Adds tri-state control configuration. |
apps/predbat/config.py |
Adds the follows-car switch. |
apps/predbat/unit_test.py |
Registers shared-control tests. |
apps/predbat/tests/test_car_charger_control.py |
Tests the shared mixin. |
apps/predbat/tests/test_ge_cloud.py |
Expands GivEnergy control tests. |
apps/predbat/tests/test_myenergi.py |
Expands Zappi control tests. |
apps/predbat/tests/test_ohme.py |
Expands Ohme control tests. |
docs/apps-yaml.md |
Documents automatic-control settings. |
docs/car-charging.md |
Documents Intelligent and guest charging. |
docs/components.md |
Updates component configuration guidance. |
tools/debug-journal.md |
Updates myenergi diagnostic notes. |
🧠 Review effort: Balanced
💡 Add a code-review agent skill or configure MCP servers for context-aware, tailored reviews. Learn more in the docs.
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.

Posted by Claude on behalf of @chalfontchubby.
Folds the former stack #5284 (shared charger-control mixin) and #5311 (control on automatically, Octopus Intelligent, guest charging) into one PR for a single final review, as Trefor suggested on #5284. It supersedes both, which will be closed once this is open. All their review threads were already answered and resolved; their commit history is kept as it was, so earlier review comments still map to commits.
Rebased onto main (8 Oct). One commit dropped: the gateway commit that moved its car plan parsing onto the shared parser, which main now has from #5120. Ohme's New Year tests from #5120 are ported to the shared control API. A local
/code-review highbefore pushing found two small bugs in the existing code, fixed in the last commit: a dispatch time with no UTC offset raised a TypeError when compared with the clock (now read as UTC), and anis_chargerof unknown/unavailable was read as "not the charger" instead of "cannot tell".Known and not changed here (from the same review): a multi-car setup shares one Octopus-discovery timer, so a second car's discovery timeout can be masked by a first car that is already wired; the Ohme charger is keyed by serial or the literal "ohme", which would orphan held state if the serial arrives late; the guest switch republishes on the next poll rather than immediately.
Part 1: shared mixin (was #5284)
Summary
Predbat-led EV charger control (start/stop the charger from the car charging plan) was implemented three times, once each in
gecloud.py(GivEnergy EV charger),myenergi.py(Zappi) andohme.py, with a fourth window parser ingateway.py. This PR moves the shared loop into one mixin,CarChargerControl(car_charger_control.py), before we turn control on automatically and add more chargers (Hypervolt, Wallbox).The mixin owns:
binary_sensor.predbat_car_charging_slot[_N]Each component keeps only what is specific to its charger: which chargers exist and in which order, whether a car is connected, how drift is detected, and the on/off/release commands. Log wording for those commands is unchanged.
One commit per step; each passes the quick suite on its own:
Behaviour changes
Intended to be a refactor, with these exceptions:
parse_car_plan_windows(). The gateway copy also moved any window starting more than 23 hours ago a year forward; a finished window now stays finished.num_cars(briefly true while auto-config'snum_carsreaches the base), an extra Zappi is now left alone instead of Stopped, matching what GivEnergy EVC already did. A charger Predbat was already holding when its car drops out ofnum_carsis released back to its own mode rather than left in the state Predbat last set.async_send_evc_command()reports a refusal by returning None, so a refused start, stop or release used to be recorded as sent and never retried; a refused release could strand a stopped charger. GE charger control now raisesEVCCommandFailedon a refusal, so nothing is recorded and the command is tried again next cycle. GE's run loop catches it as a warning, as Ohme's and myenergi's do.base.set_read_onlyis unset, the EVC loop now falls back to theset_read_onlyarg like the other chargers, not the switch entity. Predbat sets the attribute at startup (predbat.py), so this only affects test doubles.GECloudDirect.read_only_now()is kept for the inverter code that uses it.num_carskept its saved mode, so taking it back later restored that stale mode on the next release. The saved mode is now dropped once that Zappi's release goes through.Gateway control is not moved onto the mixin here: that would add release on read only, which is a behaviour change. It belongs with the follow-up that turns charger control on automatically.
Testing
tests/test_car_charger_control.pycovers the mixin against a fake component.run(), and a new mixin test covers a release that fails part-way through several chargers. Both come from an adversarial review; the Ohme test fails without the fix.num_carsbeing released, and GE control tests 11 and 12 cover a refused stop and a refused release being retried rather than recorded.tools/debug-journal.md's myenergi entry is updated for the renamed methods.charger_control_state/charger_control_release()), with the same retry until it succeeds, and feat(ohme): take the car plan from Ohme's own schedule when Predbat is not controlling the charger #5401's tests are updated for the new state names.Part 2: control on automatically (was #5311)
What this does
Stage 2 of Predbat-led EV charger control. It follows the rule agreed on #5284: if Predbat is planning the car and the user has turned on the charger's automatic setup, Predbat can control the charger without being asked separately.
Until now,
ge_cloud_evc_controlandmyenergi_zappi_controlwere off unless set. They now have three states (ohme_controlstays opt-in, see decision 2):falsetruege_cloud_evc_controlge_cloud_automatic_evcis onohme_controlmyenergi_zappi_controlmyenergi_automaticormyenergi_automatic_zappiin apps.yamlIt also adds three things, each described below:
Behaviour change on upgrade
Users who already have
ge_cloud_automatic_evcon now get charger control, and so do Zappi users who wrotemyenergi_automaticinto apps.yaml. Ohme users see no change. For each of them, Predbat starts and stops the charger unless they set its control setting tofalse.Users who already had
*_control: truesee no change, apart from the new Octopus rule and the guest switch. One part of the Octopus rule does change things for them: where Octopus drives the car itself, Predbat now leaves the charger alone unlessswitch.predbat_octopus_intelligent_charger_follows_caris on, where before it drove the charger to its plan.The docs say this in
car-charging.md, in the new section "Predbat starting and stopping your charger". This probably wants a line in the release notes.Decisions, and the options rejected
myenergi_automaticandmyenergi_automatic_zappiboth default on, so the GE/Ohme rule would switch every Zappi user over on upgrade. A Zappi that Predbat controls is Stopped between windows, so it stops diverting solar in Eco/Eco+. The options considered are inenable_control()'s docstring, for review and to tidy up later:is_chargerfrom the car's own dispatch sensor inoctopus_intelligent_slot. Both the Octopus and Kraken components publish it, so E.ON/EDF SmartFlex is covered, and a car can't be paired with another car's device. What Predbat does depends on which device Octopus drives:switch.predbat_octopus_intelligent_chargingsays. That switch only changes Predbat's own planning; Octopus keeps switching the charger either way, so driving it would fight Octopus.switch.predbat_octopus_intelligent_charger_follows_car(default off), has Predbat drive the charger instead: on during dispatches and off otherwise, so the car cannot charge on its own timers. It follows the plan and also the dispatch times on the sensor, judged against the clock, so it picks up a new dispatch without waiting for the 5-minute plan and stops the charger when the dispatch ends. Withoctopus_intelligent_chargingoff, Predbat plans the car itself and the charger follows that plan, whatever the new switch says. The Ohme follows the same rules (bbbfb3f), so with the switch onohme_control: truecan run where fix(ohme): leave the Intelligent car slots to Octopus when the Intelligent device is the car #5405 would otherwise stand it down.*_control: true, and logs a warning naming that setting (6cec384). A charger Predbat was holding is handed back as usual, so one it had stopped is not stranded. Released users are unaffected, because before this PR control only ran withtrue.switch.predbat_gecloud_guest_charging,switch.predbat_myenergi_guest_chargingandswitch.predbat_ohme_guest_charging.Fixes found in review before opening
octopus_automaticoff, Predbat waited for Octopus discovery that never came, so control never turned on."false"or a0read as on, because removing the defaults also skippedget_arg()'s boolean conversion.parse_control_setting()now normalises them.Found by a further
/code-reviewafter opening:Rebased onto main (5 Oct)
The stack is rebased onto main, which meanwhile changed the Ohme component in #5401 and #5405. How the two fit:
enable_control()is re-decided whenever the tariff or Intelligent device changes (fix(ohme): leave the Intelligent car slots to Octopus when the Intelligent device is the car #5405), and also when the follows-car or Intelligent charging switch changes while Octopus drives the car.ohme_controlleft off, Ohme's own schedule stays the car plan.Found by review after the rebase:
re:string, before its regex matches, was read as a dispatch sensor (5394c56).Not in this PR (known and deferred)
ohme_automatic_octopus_intelligent: has the same quoted-"false"problem, from before this PR.num_carsat 0 there is no plan to read, so control does nothing that cycle, including releasing a charger it holds. This comes from refactor(car): share Predbat-led EV charger control across Ohme, Zappi and GivEnergy #5284 and is unchanged.Testing
test_car_charger_control.py,test_ge_cloud.py,test_ohme.pyandtest_myenergi.py./code-review high. Their findings are the fixes listed above.🤖 Generated with Claude Code